The KYN61-40.5 40.5kV High Voltage Power Distribution Switchboard Cabinet provides reliable indoor electrical distribution with robust metal-clad construction. Designed for high voltage applications, it ensures operator safety, long-term durability, and efficient power management. Ideal for substations, industrial facilities, and commercial networks, offering precise control and maintenance-friendly operation.
Senden
The XGN2-12 Electrical Withdrawable AC Metal-Enclosed Switchgear offers reliable medium voltage distribution with enhanced safety and operational flexibility. Its withdrawable modules allow easy maintenance and replacement. Designed for indoor installations, it features robust metal enclosure, high dielectric strength, and IEC compliance, ensuring long-term performance in industrial, commercial, and utility networks.
Senden
The KYN28-12 Medium Voltage Metal Clad Armored Removable Switchgear provides reliable indoor power distribution. Featuring robust metal cladding and removable modules, it ensures safe operation, ease of maintenance, and high electrical endurance. Ideal for substations, industrial plants, and utility networks, it delivers long-term performance and efficient medium voltage management.
Senden
The fully insulated and fully enclosed main ring unit switchgear provides safe, reliable medium voltage distribution. Its compact design ensures efficient operation for indoor and outdoor substations. With robust insulation and durable enclosure, it minimizes maintenance needs while delivering long-term performance, making it ideal for urban power networks, industrial facilities, and utility applications.
Senden
The GTXGN-12 Solid Insulation Ring Main Unit Switchgear is a compact, reliable medium voltage solution for electrical distribution. Featuring solid insulation and robust construction, it ensures safe and efficient operation for indoor and outdoor substations. Ideal for urban power networks, industrial facilities, and renewable energy systems, providing long-lasting performance.
Senden
The XGN15-12 24KV SF6 Ring Main Unit (RMU) Cabinet provides reliable electrical distribution and protection for medium voltage networks. SF6 insulation ensures safe operation, while its compact and durable design suits indoor and outdoor installations. Ideal for substations and urban power grids, this RMU cabinet delivers efficient, long-lasting performance.
Senden
The SF6 Gas Insulated Switchgear is a compact, metal-enclosed solution for high and medium voltage applications. Suitable for indoor and outdoor substations, it ensures reliable electrical distribution. IEC certified, this switchgear cabinet provides safe, efficient, and durable performance for modern power systems, optimizing space without compromising safety or functionality.
Senden
MS1-12-630/20-01, Abbreviation: MS1-01, MS1-12-630/25-02, Abbreviation: MS1-02, Suitable for SF6 gas-insulated ring main units.
Senden
MS1-12-630/20-01, Abbreviation: APMS1-01, MS1-12-630/25-02, Abbreviation: APMS1-02, Suitable for SF6 gas-insulated ring main units.
Senden
MS2 Three-Phase Circuit Breaker, MS2-12-630/20-01 Abbreviation: APMS2-01, MS2-12-630/25-02 Abbreviation: APMS2-02, MS2-12-630/20-03 Abbreviation: APMS2-03, MS2-12-630/25-04 Abbreviation: APMS2-04, MS2-12-1000/20-05 Abbreviation: APMS2-05, MS2-12-1000/25-06 Abbreviation: APMS2-06, Suitable for air-insulated switchgear.
Senden
MS2 Single-Phase Circuit Breaker, MS2-12-630/20-21 Abbreviation: APMS2-21, MS2-12-630/25-22 Abbreviation: APMS2-22, Suitable for air-insulated switchgear, and used in applications such as phase selection and bypass switching.
Senden
MS4 Post-Insulated Three-Phase Circuit Breaker, MS4-12-1250/25-01 Abbreviation: APMS4-01 (For SF6 gas-filled switchgear), MS4-12-1250A/31.5-02 Abbreviation: APMS4-02 (For SF6 gas-filled switchgear), MS4-12-1250/25-03 Abbreviation: APMS4-03 (For air-insulated switchgear), MS4-12-1250A/31.5-04 Abbreviation: APMS4-04 (For air-insulated switchgear),
Senden
MS4 Post-Insulated Single-Phase Circuit Breaker, MS4-12-1250/25-05 Abbreviation: MS4-05, MS4-12-1250/31.5-06 Abbreviation: MS4-06, For air-insulated switchgear, used in arc suppression, fault line selection, phase selection, and bypass switching operations.
Senden
APMS5 SHELL Frame-Type Single-Phase Circuit Breaker APMS5-12-1250/25-21 Abbreviation: APMS5-21 APMS5-12-1250/31.5-22 Abbreviation: APMS5-22 APMS5-12-1600/25-23 Abbreviation: APMS5-23 MS5-12-1600/31.5-24 Abbreviation: APMS5-24, MS5-12-2000/25-25 Abbreviation: APMS5-25, MS5-12-2000/31.5-26 Abbreviation: APMS5-26, For use in air-insulated switchgear.
Senden
MS5 SHELL Frame-Type Three-Phase Circuit Breaker, MS5-12-1250/25-07 Abbreviation: MS5-07, MS5-12-1250/31.5-08 Abbreviation: MS5-08, MS5-12-1600/25-09 Abbreviation: MS5-09, MS5-12-1600/31.5-10 Abbreviation: MS5-10, MS5-12-2000/25-11 Abbreviation: MS5-11, MS5-12-2000/31.5-12 Abbreviation: MS5-12 For use in air-insulated switchgear.
Senden
MD-01, 02, 03 Circuit Breaker Drive/Operating Module Model: MD-DC-24V-01 Abbreviation: MD-01 Model: MD-DC-48V-02 Abbreviation: MD-02 Model: MD-AC/DC-110/220V-03 Abbreviation: MD-03 Suitable for standard applications.
Senden
MD-04 Circuit Breaker Operating Module Model: MD-DC-48V-04 Abbreviation: MD-04 Dedicated module for China Southern Power Grid (CSG) bidding.