Anmeldung | registrieren
产品中心
Zuhause > Produktcenter
Anzeigemethode  
 
  • KYN61-40.5 40.5kV High Voltage Power Distribution Switchboard Cabinet Metal Clad Switchgear Indoor

    KYN61-40.5 40.5kV High Voltage Power Distribution Switchboard Cabinet Metal Clad Switchgear Indoor

    The KYN61-40.5 40.5kV High Voltage Power Distribution Switchboard Cabinet provides reliable indoor electrical distribution with robust metal-clad construction. Designed for high voltage applications, it ensures operator safety, long-term durability, and efficient power management. Ideal for substations, industrial facilities, and commercial networks, offering precise control and maintenance-friendly operation.

    Senden
  • XGN2-12 Electrical Withdrawable AC Metal-Enclosed Switchgear

    XGN2-12 Electrical Withdrawable AC Metal-Enclosed Switchgear

    The XGN2-12 Electrical Withdrawable AC Metal-Enclosed Switchgear offers reliable medium voltage distribution with enhanced safety and operational flexibility. Its withdrawable modules allow easy maintenance and replacement. Designed for indoor installations, it features robust metal enclosure, high dielectric strength, and IEC compliance, ensuring long-term performance in industrial, commercial, and utility networks.

    Senden
  • YN28-12 Medium Voltage Metal Clad Armored Removable Switchgear Medium Voltage Power Distribution Cabinet Indoor

    YN28-12 Medium Voltage Metal Clad Armored Removable Switchgear Medium Voltage Power Distribution Cabinet Indoor

    The KYN28-12 Medium Voltage Metal Clad Armored Removable Switchgear provides reliable indoor power distribution. Featuring robust metal cladding and removable modules, it ensures safe operation, ease of maintenance, and high electrical endurance. Ideal for substations, industrial plants, and utility networks, it delivers long-term performance and efficient medium voltage management.

    Senden
  • Fully insulated and fully enclosed main ring unit switchgear

    Fully insulated and fully enclosed main ring unit switchgear

    The fully insulated and fully enclosed main ring unit switchgear provides safe, reliable medium voltage distribution. Its compact design ensures efficient operation for indoor and outdoor substations. With robust insulation and durable enclosure, it minimizes maintenance needs while delivering long-term performance, making it ideal for urban power networks, industrial facilities, and utility applications.

    Senden
  • GTXGN-12 Solid Insulation Ring Main Unit Switchgear

    GTXGN-12 Solid Insulation Ring Main Unit Switchgear

    The GTXGN-12 Solid Insulation Ring Main Unit Switchgear is a compact, reliable medium voltage solution for electrical distribution. Featuring solid insulation and robust construction, it ensures safe and efficient operation for indoor and outdoor substations. Ideal for urban power networks, industrial facilities, and renewable energy systems, providing long-lasting performance.

    Senden
  • XGN15-12 24KV SF6 Ring Main Unit RMU Cabine

    XGN15-12 24KV SF6 Ring Main Unit RMU Cabine

    The XGN15-12 24KV SF6 Ring Main Unit (RMU) Cabinet provides reliable electrical distribution and protection for medium voltage networks. SF6 insulation ensures safe operation, while its compact and durable design suits indoor and outdoor installations. Ideal for substations and urban power grids, this RMU cabinet delivers efficient, long-lasting performance.

    Senden
  • SF6 Gas Insulated Switchgear Metal Enclosed High Voltage Medium Voltage Indoor Outdoor Compact Design IEC Certified Substation Electrical Distribution Cabinet

    SF6 Gas Insulated Switchgear Metal Enclosed High Voltage Medium Voltage Indoor Outdoor Compact Design IEC Certified Substation Electrical Distribution Cabinet

    The SF6 Gas Insulated Switchgear is a compact, metal-enclosed solution for high and medium voltage applications. Suitable for indoor and outdoor substations, it ensures reliable electrical distribution. IEC certified, this switchgear cabinet provides safe, efficient, and durable performance for modern power systems, optimizing space without compromising safety or functionality.

    Senden
  • MS1 Three-Phase Circuit Breaker

    MS1 Three-Phase Circuit Breaker

    MS1-12-630/20-01, Abbreviation: MS1-01, MS1-12-630/25-02, Abbreviation: MS1-02, Suitable for SF6 gas-insulated ring main units.

    Senden
  • MS1 Three-Phase Circuit Breaker

    MS1 Three-Phase Circuit Breaker

    MS1-12-630/20-01, Abbreviation: APMS1-01, MS1-12-630/25-02, Abbreviation: APMS1-02, Suitable for SF6 gas-insulated ring main units.

    Senden
  • MS2 Three-Phase Circuit Breaker

    MS2 Three-Phase Circuit Breaker

    MS2 Three-Phase Circuit Breaker, MS2-12-630/20-01 Abbreviation: APMS2-01, MS2-12-630/25-02 Abbreviation: APMS2-02, MS2-12-630/20-03 Abbreviation: APMS2-03, MS2-12-630/25-04 Abbreviation: APMS2-04, MS2-12-1000/20-05 Abbreviation: APMS2-05, MS2-12-1000/25-06 Abbreviation: APMS2-06, Suitable for air-insulated switchgear.

    Senden
  • APMS2 Single-Phase Circuit Breaker

    APMS2 Single-Phase Circuit Breaker

    MS2 Single-Phase Circuit Breaker, MS2-12-630/20-21 Abbreviation: APMS2-21, MS2-12-630/25-22 Abbreviation: APMS2-22, Suitable for air-insulated switchgear, and used in applications such as phase selection and bypass switching.

    Senden
  • MS1(G)3-phases VC

    MS1(G)3-phases VC

    MS1(G)3-phases VC

    Senden
  • MS4 Post-Insulated Three-Phase Circuit Breaker

    MS4 Post-Insulated Three-Phase Circuit Breaker

    MS4 Post-Insulated Three-Phase Circuit Breaker, MS4-12-1250/25-01 Abbreviation: APMS4-01 (For SF6 gas-filled switchgear), MS4-12-1250A/31.5-02 Abbreviation: APMS4-02 (For SF6 gas-filled switchgear), MS4-12-1250/25-03 Abbreviation: APMS4-03 (For air-insulated switchgear), MS4-12-1250A/31.5-04 Abbreviation: APMS4-04 (For air-insulated switchgear),

    Senden
  • MS4 Post-Insulated Single-Phase Circuit Breaker

    MS4 Post-Insulated Single-Phase Circuit Breaker

    MS4 Post-Insulated Single-Phase Circuit Breaker, MS4-12-1250/25-05 Abbreviation: MS4-05, MS4-12-1250/31.5-06 Abbreviation: MS4-06, For air-insulated switchgear, used in arc suppression, fault line selection, phase selection, and bypass switching operations.

    Senden
  • MS5 SHELL Frame-Type Single-Phase Circuit Breaker

    MS5 SHELL Frame-Type Single-Phase Circuit Breaker

    APMS5 SHELL Frame-Type Single-Phase Circuit Breaker APMS5-12-1250/25-21 Abbreviation: APMS5-21 APMS5-12-1250/31.5-22 Abbreviation: APMS5-22 APMS5-12-1600/25-23 Abbreviation: APMS5-23 MS5-12-1600/31.5-24 Abbreviation: APMS5-24, MS5-12-2000/25-25 Abbreviation: APMS5-25, MS5-12-2000/31.5-26 Abbreviation: APMS5-26, For use in air-insulated switchgear.

    Senden
  • MS5 SHELL Frame-Type Three-Phase Circuit Breaker

    MS5 SHELL Frame-Type Three-Phase Circuit Breaker

    MS5 SHELL Frame-Type Three-Phase Circuit Breaker, MS5-12-1250/25-07 Abbreviation: MS5-07, MS5-12-1250/31.5-08 Abbreviation: MS5-08, MS5-12-1600/25-09 Abbreviation: MS5-09, MS5-12-1600/31.5-10 Abbreviation: MS5-10, MS5-12-2000/25-11 Abbreviation: MS5-11, MS5-12-2000/31.5-12 Abbreviation: MS5-12 For use in air-insulated switchgear.

    Senden
  • MD-01, 02, 03 Circuit Breaker Drive/Operating Module

    MD-01, 02, 03 Circuit Breaker Drive/Operating Module

    MD-01, 02, 03 Circuit Breaker Drive/Operating Module Model: MD-DC-24V-01 Abbreviation: MD-01 Model: MD-DC-48V-02 Abbreviation: MD-02 Model: MD-AC/DC-110/220V-03 Abbreviation: MD-03 Suitable for standard applications.

    Senden
  • MD-04 Circuit Breaker Operating Module

    MD-04 Circuit Breaker Operating Module

    MD-04 Circuit Breaker Operating Module Model: MD-DC-48V-04 Abbreviation: MD-04 Dedicated module for China Southern Power Grid (CSG) bidding.

    Senden
Summe253, Pro Seite:18Artikel

Contact Information

Indiana Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

New York Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

Search

Diese Website verwendet Cookies, um sicherzustellen, dass Sie das beste Erlebnis auf unserer Website erhalten.

Akzeptieren ablehnen